V Series double pumps Details

V Series double pumps


      Shape and introduction These series of composition vane pumps in high performance are developed for industrial application. They can be applied properly in the hydraulic system of plastic injection machinery, rubber machinery, casting machiner, machine tool industry, etc.

The main features are:
1. The designing structure of composition vanes reduces its impact on the stator, so the pumps will have further stability and longer lifetime while working with high pressure and high speed.
2. The designing structure of composition vanes itself reduces the noise. The design of 12 vanes makes smaller flow pulsation and lower noise.
3. Multi-displacement option and the cartridge structure of pump core make flexible application and casy maintcnance.

 

 

Model descriptions:

(F3-) ****V ** A ** (F) -** * 22 *
Front marks Code of series Displacement code shaft end pump Pump port
connection
Displacement code
cover end pump
Mounting
type
Shaft extension Pump
position
Designing No. Direction of
rotation

No mark:
water-in oil
emulsion of
petroleum
series

F3:
Sul phosuccinid
ester fatty
of acid

2520V 10,12.14,15,17,
19.21

A-SAE

4 Bolted
flange

2,3,4,5,6.7.8,9,
10,11.12,14
No mark-flangel
mounting
F-
foot
mounting

1-straight shaft
with key
86-heavy-duty
straight shaft
with key

11-spline shaft

See as the
following
table
22 (viewed from the
shaft end of the pump)
L-counterclockwise
rotation
R-clockwise rotation
3520V 21,25,30,32,35,
38,45
2,3,4,5,6,7,8,9,
10,11,12,14
3525V 21,25,30,32,35,
38,45
10,12,14,15,17,
19,21
4520V 42,45,50,57,60,
66,75
2,3,4,5,6,7,8,9,
10,11,12,14
4525V 42,45,50,57,60,
66,75
10,12,14,15,17,.
19,21
4535V 42,45,50,57,60,
66,75
21,25,30,32,35,
38,45

♦The rated displacement(USgpm) is under the conditions of 1200r/min and 0.69Mpa(100psi).

Pump oil port position(viewed from cover end pump)


Pump position All series(except for 4535V) 4535V
The first outlet is
the opposition
side of inlet.
AA The second outlet is to counterclockwise rotation of 135°from inlet The second outlet is the opposition side of inlet.
AB The second outlet is to counterclockwise rotation of 45°from inlet The second outlet is to countercleckwise rotation of 90° from inlet
AC The second outlet is to clockwise rotation of 45°from inlet The second outlet is the same side of inlet.
AD The second outlet is to clockwise rofation of 135° from inlet The second outlet is to clockwise rotation of 90°from inlet
The first outlet is
to counterclockwisd
rotation of 90°
from inlet
BA The second outlet is to counterclockwise rotation of 135°from inlet The second outlet is the opposition side of inlet.
BB The second outlet is to counterclockwise rotation of 45°from inlet

The second outlet is to counterclockwise rotation of 90° from inlet

BC The second outlct is to clockwise rotation of 45°from inlet The second outlet is the same side of inlet.
BD The second outlet is to clockwise rotation of 135° from inlet The second outlet is to clockwise rotation of 90°from inlet
The first outlet is
the same side
of inlet
CA The second outlet is to counterclockwise rotation of 135°from inlet The second outlet is the opposition side of inlet.
CB The second outlet is to counterclockwise rotation of 45°from inlet The second outlet is to counterclockwise rotation of 90°from inlet
CC The second outlet is to clockwise rotation of 45°from inlet The second outlet is the same side of inlet.
CD The second outlet is to clockwise rotation of 135°from inlet The second outlet is to clockwise rotation of 90° from inlet
The first outlet is
to clockwise
rotation of 90°
from inlet
DA The second outlet is to clockwise rotation of 135°from inlet The second outles is the opposition side of inlet.
DB The second outlet is to counterclockwise rotation of 45°from inlet The second outlet is to counterclockwise rotation of 90°from inlet
DC The second outlet is to clockwise rotation of 45°from inlet The sccond outlet is the same side of inlet.
DD The second outlet is to counterclockwise rolation of 135°from inlet The second outlet is to clockwise rotation of 90°from inlet

Installation sizes


2520V,35**V和452*V

Models Φa ×all screw holes.4 holes Φb×all screw holes,4 holes Φc x all screw holes.4 holes
2520V 1/2-13UNC-2Bx23.8 depth 3/8-16UNC-2B x 20.I depth 3/8-15UNC-2Bx20.1 depth
3520V 5/8-1lUNC-2Bx25.4 depth 7/16-14UNC-2B ×21.0 depth 3/8-15UNC-2Bx20.1 depth
3525V 5/8-llUNC-2B×25.4 depth 7/16-14UNC-2Bx21.0 depth 3/8-15UNC-2Bx20.1 depth
4520V 5/8-1lUNC-2Bx25.4 depth 1/2-13UNC-2B ×23.8 depth 3/8-15UNC-2Bx20,I depth
4525V 5/8-lIUNC-2Bx25.4 depth 1/2-13UNC-2B x23.8 depth 3/8-15UNC-2Bx20.1 depth

 

Models A B C D E F G H J K L M N P Q
2520V 50.8 26.2 12.7 25.4 52.4 101-6/101.5 9.53 63.5 88.9 19.1 75.2 75.2 88.1 101.6 38.1
3520V 62 30.1 15.9 31.7 58.7 127/126.9 9.53 76.2 106.3 19.1 75.2 75.2 99.6 114.3 38.1
3525V 62 30.1 15.9 31.7 58.7 127/126.9 9.53 76.2 106.3 25.4 74.7 74.7 109.5 114.3 38.1
4520V 69.9 35.7 15.9 38.1 69.9 127/126.9 12.7 88.9 120.6 19.1 75.2 75.2

120 119.4 42.9
4525V 69.9 35.7 15.9 38.1 69.9 127/126.9 12.7 88.9 120.6 25.4 74.7 74.7 136 119.4 42.9

 

Models R S T U V W X Z
2520V 76.2 250 85.3 146.1 120 174.7 22.2 47.6
3520V 82.6 273.3 88.9 181 148 213 22.2 47.6
3525V 82.6 287.3 88.9 181 148 213 26.2 52.4
4520V 93.7 303.5 102.4 181 148 213 22.2 47.6
4525V 93.7 .25 102.4 181 148 213 26.2 52.4

Installation sizes


45335V

Operation and Maintenance

♦Hydraulic oil

It is recommended to adopt anti-wear hydraulie fluids with viscosity of 32est-68est under the temperature of 40℃, or automobile crankcase oil with alphabetic marks of SC, SD, SE or SF. The recommended viscosity under rated rotation speed and rated pressure should range from 13est to 54est with the temperature range of49℃ to 65℃.

♦Cold start

In the case of adopting SAE 10W type hydraulic oil with viscosity between 860cst and 54est, the operating rotation speed and pressure shall be limited within 50% of rated rotation speed and rated pressure respectively, until the system warms up. Particular attention should be paid to make sure that the whole system including the cylinder and motor on the far away side shall be all warmed up, when the pump starts up with the hydraulic oil viscosity exceeding 860cst.

♦High temperature operation

While working under high temperature, the viscosity shall not be less than 13est, and the temperature shall not exceed 99℃. Otherwise, the service lifetime of pump core components and sealing parts will be reduced.

♦Noise data

The average conditions for noise value testing of series of pumps:

1.Test with rotation speed of 1500r/min in mute laboratory.
2.Anti-wear hydraulic oil with the viscosity of 30cst.
3.The testing temperature of hydraulic oil ranges from 45℃ to 50℃.
4.The distance between the noise sampling site and the back side of pump shall be one meter away.